Explosion vented equipment system protection guide / (Record no. 69364)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 04645cam a22006018i 4500 |
001 - CONTROL NUMBER | |
control field | on1157360103 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20220711203622.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 200518s2020 nju o 001 0 eng |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781119640059 |
-- | (electronic bk. : oBook) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 1119640059 |
-- | (electronic bk. : oBook) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781119640073 |
-- | (epub) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 1119640075 |
-- | (epub) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781119640066 |
-- | (adobe pdf) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 1119640067 |
-- | (adobe pdf) |
029 1# - (OCLC) | |
OCLC library identifier | UKMGB |
System control number | 019991548 |
037 ## - | |
-- | 9781119640073 |
-- | Wiley |
082 00 - CLASSIFICATION NUMBER | |
Call Number | 628.9/22 |
100 1# - AUTHOR NAME | |
Author | Comer, Robert Charles, |
245 10 - TITLE STATEMENT | |
Title | Explosion vented equipment system protection guide / |
250 ## - EDITION STATEMENT | |
Edition statement | First edition. |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | 1 online resource |
505 0# - FORMATTED CONTENTS NOTE | |
Remark 2 | Structural Analysis and Design for Reinforcing Dust Handling Systems. Part 1: Introduction -- Design Criteria and General Theory -- Square/Rectangular Dust Collector Wall, Roof, and Hopper Sections -- Round/Cylindrical Dust Collectors -- Reinforcing Member to Panel Weld Analyses and Port (Nozzle) Weld Analyses -- Access Doors, Hinges, and Latches -- Explosion Vent Ducts, Mill Inlet Air Ducts, Blast Deflectors, and Filter Bag Cage Design -- Explosion Vent Duct Weather Covers -- Dust Collector Stability -- System Explosion Isolation -- Screw Conveyors, Rotary Airlock Valves, and Isolation Valves -- Grounding of Systems -- Housekeeping and General Information -- Appendix A: Part 1: Worksheet -- Explosion Relief Element and Explosion Flowing Pressure Analyses. Part 2: Introduction -- Know Your Process Dust Characteristics -- Venting Analysis of Dust Handling Systems -- Duct Back Pressure Considerations -- Other Methods of Explosion Pressure Reduction -- Appendix B: Part 2: Worksheet. |
500 ## - GENERAL NOTE | |
Remark 1 | Includes index. |
520 ## - SUMMARY, ETC. | |
Summary, etc | "The U.S. Chemical Safety Board reports 316 dust explosions over the last 30 years that caused 145 workers killed and 846 injured with extensive damage to facilities. Fines by OSHA have totaled more than $100,000,000. According to the independent 2019 (mid-year) combustible dust incident report from Dustex Research, Ltd, there were 80 dust related fires, 19 dust related explosions, 72 injuries and one fatality in the U.S. from January through July 2019. There are more than 130,000 establishments in the U.S., many with more than one facility, with many dust collection systems per facility. The new National Fire Protection Agency directive, NFPA 652, "Standard on the Fundamentals of Combustible Dust", requires all facilities to complete a DHA (Dust Hazard Analysis) by September 2020. Required is a systematic review to identify and evaluate potential dust fire, flash fire and explosion hazards in a process or facility where combustible or explosive material is handled or processed. The result of these analyses will disclose dust collection systems that present a risk of catastrophic failure that will require mitigation. Most facilities do not have a licensed structural engineer or stress analyst on staff that has the experience to perform the analysis to make the equipment safe. This book provides the information required to mitigate equipment, facilities and personnel at risk"-- |
590 ## - LOCAL NOTE (RLIN) | |
Local note | John Wiley and Sons |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
General subdivision | Equipment and supplies. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
General subdivision | Equipment and supplies. |
650 #7 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
General subdivision | Equipment and supplies |
650 #7 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
General subdivision | Equipment and supplies |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | https://doi.org/10.1002/9781119640059 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | eBooks |
264 #1 - | |
-- | Hoboken, NJ, USA : |
-- | John Wiley & Sons, |
-- | 2020. |
336 ## - | |
-- | text |
-- | txt |
-- | rdacontent |
337 ## - | |
-- | computer |
-- | n |
-- | rdamedia |
338 ## - | |
-- | online resource |
-- | nc |
-- | rdacarrier |
520 ## - SUMMARY, ETC. | |
-- | Provided by publisher. |
588 ## - | |
-- | Description based on print version record and CIP data provided by publisher; resource not viewed. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Dust control |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Fire prevention |
650 #7 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Dust control |
-- | (OCoLC)fst00899654 |
650 #7 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Fire prevention |
-- | (OCoLC)fst00925469 |