Development of Implantable Electronics as Novel Approaches to Obstructive Sleep Apnea (Record no. 77945)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03274nam a22005415i 4500 |
001 - CONTROL NUMBER | |
control field | 978-981-15-8327-8 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20220801215851.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 201009s2021 si | s |||| 0|eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9789811583278 |
-- | 978-981-15-8327-8 |
082 04 - CLASSIFICATION NUMBER | |
Call Number | 610.28 |
100 1# - AUTHOR NAME | |
Author | Seo, Jungmin. |
245 10 - TITLE STATEMENT | |
Title | Development of Implantable Electronics as Novel Approaches to Obstructive Sleep Apnea |
250 ## - EDITION STATEMENT | |
Edition statement | 1st ed. 2021. |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | XVII, 75 p. 46 illus., 34 illus. in color. |
490 1# - SERIES STATEMENT | |
Series statement | Springer Theses, Recognizing Outstanding Ph.D. Research, |
505 0# - FORMATTED CONTENTS NOTE | |
Remark 2 | Introduction -- Methods -- Results -- Discussions -- Conclusion. . |
520 ## - SUMMARY, ETC. | |
Summary, etc | This book addresses novel methods to treat a very popular disease, obstructive sleep apnea, based on a knowledge of an electrical engineering. Two approaches are given in the book using an upper-airway stimulation based on the pathogenesis of an obstructive sleep apnea. Implantable electronics are devised to control the tongue and the soft palate considering that they are the major pharyngeal muscles contributing to the apnea. First, for tongue control, a cuff electrode was designed and fabricated to stimulate the hypoglossal nerve, which innervates to the tongue muscle. Rare-earth magnets were embedded in the cuff for easy and repeatable installation of the electrode. For soft palate control, a palatal implant system was firstly developed to contract the soft palate muscle by applying electrical stimuli. Comprised of an implant, an intra-oral device, and an external controller, the palatal implant system is fully powered and controlled by means of wireless communication. The approaches were demonstrated in both in vitro and in vivo assessments, in collaboration with department of Otorhinolaryngology, Seoul National University Bundang Hospital. . |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | https://doi.org/10.1007/978-981-15-8327-8 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | eBooks |
264 #1 - | |
-- | Singapore : |
-- | Springer Nature Singapore : |
-- | Imprint: Springer, |
-- | 2021. |
336 ## - | |
-- | text |
-- | txt |
-- | rdacontent |
337 ## - | |
-- | computer |
-- | c |
-- | rdamedia |
338 ## - | |
-- | online resource |
-- | cr |
-- | rdacarrier |
347 ## - | |
-- | text file |
-- | |
-- | rda |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biomedical engineering. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronics. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronic circuits. |
650 14 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Biomedical Engineering and Bioengineering. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronics and Microelectronics, Instrumentation. |
650 24 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electronic Circuits and Systems. |
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE | |
-- | 2190-5061 |
912 ## - | |
-- | ZDB-2-ENG |
912 ## - | |
-- | ZDB-2-SXE |
No items available.