Dynamic x-ray imaging systems used in medicine : (Record no. 82869)

000 -LEADER
fixed length control field 04494nam a2200721 i 4500
001 - CONTROL NUMBER
control field 9780750338196
003 - CONTROL NUMBER IDENTIFIER
control field IOP
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20230516170251.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m eo d
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field cr cn |||m|||a
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211108s2021 enka fob 000 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9780750338196
Qualifying information ebook
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9780750338189
Qualifying information mobi
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
Canceled/invalid ISBN 9780750338172
Qualifying information print
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
Canceled/invalid ISBN 9780750338202
Qualifying information myPrint
024 7# - OTHER STANDARD IDENTIFIER
Standard number or code 10.1088/978-0-7503-3819-6
Source of number or code doi
035 ## - SYSTEM CONTROL NUMBER
System control number (CaBNVSL)thg00082711
035 ## - SYSTEM CONTROL NUMBER
System control number (OCoLC)1273668826
040 ## - CATALOGING SOURCE
Original cataloging agency CaBNVSL
Language of cataloging eng
Description conventions rda
Transcribing agency CaBNVSL
Modifying agency CaBNVSL
050 #4 - LIBRARY OF CONGRESS CALL NUMBER
Classification number RC78.5
Item number .D969 2021eb
060 #4 - NATIONAL LIBRARY OF MEDICINE CALL NUMBER
Classification number WN 150
Item number D997 2021eb
072 #7 - SUBJECT CATEGORY CODE
Subject category code M
Source bicssc
072 #7 - SUBJECT CATEGORY CODE
Subject category code TEC000000
Source bisacsh
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 681/.761
Edition number 23
245 00 - TITLE STATEMENT
Title Dynamic x-ray imaging systems used in medicine :
Remainder of title quality control in performance characteristics /
Statement of responsibility, etc. edited by Greg Stevens.
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture Bristol [England] (Temple Circus, Temple Way, Bristol BS1 6HG, UK) :
Name of producer, publisher, distributor, manufacturer IOP Publishing,
Date of production, publication, distribution, manufacture, or copyright notice [2021]
300 ## - PHYSICAL DESCRIPTION
Extent 1 online resource (various pagings) :
Other physical details illustrations (some color).
336 ## - CONTENT TYPE
Content type term text
Source rdacontent
337 ## - MEDIA TYPE
Media type term electronic
Source isbdmedia
338 ## - CARRIER TYPE
Carrier type term online resource
Source rdacarrier
490 1# - SERIES STATEMENT
Series statement [IOP release $release]
490 1# - SERIES STATEMENT
Series statement IPEM-IOP series in physics and engineering in medicine and biology
490 1# - SERIES STATEMENT
Series statement IOP ebooks. [2021 collection]
500 ## - GENERAL NOTE
General note "Version: 202110"--Title page verso.
500 ## - GENERAL NOTE
General note "IPEM report number 32, part VIII"--Page ix.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references.
505 0# - FORMATTED CONTENTS NOTE
Formatted contents note 1. Introduction -- 1.1. Scope of this report -- 1.2. Preface -- 1.3. Rationale for the approach used -- 1.4. What makes dynamic x-ray systems different?
505 8# - FORMATTED CONTENTS NOTE
Formatted contents note 2. Dynamic imaging systems -- 2.1. Overview -- 2.2. Automatic dose rate control (ADRC) -- 2.3. Additional features of dynamic imaging systems -- 2.4. Introduction to QC of dynamic imaging systems
505 8# - FORMATTED CONTENTS NOTE
Formatted contents note 3. Radiation protection and tube output tests -- 3.1. Introduction -- 3.2. Measurements -- 3.3. Dosimetry tests -- 3.4. Dosimeter selection -- 3.5. Detector air KERMA rate (DAKR) -- 3.6. Patient entrance surface air KERMA rate (ESAKR)
505 8# - FORMATTED CONTENTS NOTE
Formatted contents note 4. Technical image quality tests -- 4.1. Factors influencing technical image quality in dynamic imaging -- 4.2. Approaches to image quality assessment in dynamic imaging -- 4.3. Assessment of detector technical image quality using test objects
505 8# - FORMATTED CONTENTS NOTE
Formatted contents note 5. Physical performance evaluation -- 5.1. Response function -- 5.2. Detector brightness uniformity -- 5.3. Variance image -- 5.4. Noise separation using variance -- 5.5. Noise power spectrum (NPS) -- 5.6. Modulation transfer function (MTF) -- 5.7. Lag -- 5.8. Example data.
520 3# - SUMMARY, ETC.
Summary, etc. This book is intended to facilitate the testing of dynamic imaging systems to ensure safety of the systems. The aim is to discuss methods and techniques that may be used to commission and perform quality control (QC) measurements of dynamic x-ray imaging systems; the primary function of which is real time imaging to provide visualization of dynamic anatomical and other processes as they occur.
521 ## - TARGET AUDIENCE NOTE
Target audience note Medical physicists in diagnostic radiology.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Also available in print.
538 ## - SYSTEM DETAILS NOTE
System details note Mode of access: World Wide Web.
538 ## - SYSTEM DETAILS NOTE
System details note System requirements: Adobe Acrobat Reader, EPUB reader, or Kindle reader.
545 ## - BIOGRAPHICAL OR HISTORICAL DATA
Biographical or historical data Greg Stevens is principal clinical scientist in diagnostic radiology, having worked in Plymouth Hospital since obtaining HCPC registration. He has a strong practical and research interest in non-invasive surgical procedures and the technologies that enable this.
588 0# - SOURCE OF DESCRIPTION NOTE
Source of description note Title from PDF title page (viewed on November 8, 2021).
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Radiography, Medical
General subdivision Equipment and supplies
-- Testing.
9 (RLIN) 70596
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Radiography, Medical
General subdivision Safety measures.
9 (RLIN) 70597
650 12 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Radiography
General subdivision instrumentation.
9 (RLIN) 70598
650 22 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Equipment Safety.
9 (RLIN) 70599
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Medicine.
Source of heading or term bicssc
9 (RLIN) 11158
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Medical physics and biophysics.
Source of heading or term bisacsh
9 (RLIN) 70121
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Stevens, Gregory C.,
Relator term editor.
9 (RLIN) 70600
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Institute of Physics (Great Britain),
Relator term publisher.
9 (RLIN) 11622
776 08 - ADDITIONAL PHYSICAL FORM ENTRY
Relationship information Print version:
International Standard Book Number 9780750338172
-- 9780750338202
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE
Uniform title IOP (Series).
Name of part/section of a work Release 21.
9 (RLIN) 70601
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE
Uniform title IPEM-IOP series in physics and engineering in medicine and biology.
9 (RLIN) 70161
830 #0 - SERIES ADDED ENTRY--UNIFORM TITLE
Uniform title IOP ebooks.
Name of part/section of a work 2021 collection.
9 (RLIN) 70602
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://iopscience.iop.org/book/978-0-7503-3819-6">https://iopscience.iop.org/book/978-0-7503-3819-6</a>
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type eBooks

No items available.