000 | 03461nam a22005415i 4500 | ||
---|---|---|---|
001 | 978-3-642-41323-0 | ||
003 | DE-He213 | ||
005 | 20200421111657.0 | ||
007 | cr nn 008mamaa | ||
008 | 131120s2014 gw | s |||| 0|eng d | ||
020 |
_a9783642413230 _9978-3-642-41323-0 |
||
024 | 7 |
_a10.1007/978-3-642-41323-0 _2doi |
|
050 | 4 | _aTK7881.15 | |
072 | 7 |
_aTHRD _2bicssc |
|
072 | 7 |
_aTHRM _2bicssc |
|
072 | 7 |
_aTEC046000 _2bisacsh |
|
082 | 0 | 4 |
_a621.317 _223 |
100 | 1 |
_aLam, Chi-Seng. _eauthor. |
|
245 | 1 | 0 |
_aDesign and Control of Hybrid Active Power Filters _h[electronic resource] / _cby Chi-Seng Lam, Man-Chung Wong. |
264 | 1 |
_aBerlin, Heidelberg : _bSpringer Berlin Heidelberg : _bImprint: Springer, _c2014. |
|
300 |
_aXVI, 158 p. 92 illus., 15 illus. in color. _bonline resource. |
||
336 |
_atext _btxt _2rdacontent |
||
337 |
_acomputer _bc _2rdamedia |
||
338 |
_aonline resource _bcr _2rdacarrier |
||
347 |
_atext file _bPDF _2rda |
||
490 | 1 |
_aSpringerBriefs in Electrical and Computer Engineering, _x2191-8112 |
|
505 | 0 | _aIntroduction -- Analysis of HAPF in Harmonic Resonances Prevention and Compensation Capabilities -- Nonlinearity and Linearization of Hysteresis PWM Study and Analysis for HAPF -- Adaptive DC-Link Voltage Control Technique for HAPF in Reactive Power Compensation -- Minimum Inverter Capacity Design for HAPF -- Design and Performance of A 220V 10kVA Adaptive Low DC-Link Voltage Controlled HAPF With A Coupling Neutral Inductor Experimental System -- Conclusions and Prospective for Future Work -- Appendix. | |
520 | _aDesign and Control of Hybrid Active Power Filters presents an overview of the current quality problems and their compensators. To get a balance between the system cost and performance, hybrid active power filters (HAPFs) are valuable. The book presents the coverage of resonance phenomena prevention capability, filtering performance and system robustness analysis of HAPF; nonlinear inverter current slope characteristics and their linear operation region requirement analysis of the hysteresis PWM for the HAPF; minimum inverter capacity design procedure of HAPF, adaptive dc-link voltage controller for the HAPF and the real design example of a 220V 10kVA HAPF, in which the system performance analysis method, minimum dc voltage deduction concept and adaptive dc voltage idea can be further extended into the other active compensators, such as APF, static synchronous compensator STATCOM, etc. This book will benefit researchers, graduate students, and electrical power engineers in the field of power-quality compensation. Dr. Chi-Seng Lam and Dr. Man-Chung Wong are both from the University of Macau, Macao, China. | ||
650 | 0 | _aEngineering. | |
650 | 0 | _aEnergy systems. | |
650 | 0 | _aControl engineering. | |
650 | 0 | _aElectronic circuits. | |
650 | 0 | _aPower electronics. | |
650 | 1 | 4 | _aEngineering. |
650 | 2 | 4 | _aPower Electronics, Electrical Machines and Networks. |
650 | 2 | 4 | _aCircuits and Systems. |
650 | 2 | 4 | _aControl. |
650 | 2 | 4 | _aEnergy Systems. |
700 | 1 |
_aWong, Man-Chung. _eauthor. |
|
710 | 2 | _aSpringerLink (Online service) | |
773 | 0 | _tSpringer eBooks | |
776 | 0 | 8 |
_iPrinted edition: _z9783642413223 |
830 | 0 |
_aSpringerBriefs in Electrical and Computer Engineering, _x2191-8112 |
|
856 | 4 | 0 | _uhttp://dx.doi.org/10.1007/978-3-642-41323-0 |
912 | _aZDB-2-ENG | ||
942 | _cEBK | ||
999 |
_c54786 _d54786 |