000 | 02876nam a22004935i 4500 | ||
---|---|---|---|
001 | 978-3-319-10052-4 | ||
003 | DE-He213 | ||
005 | 20200421112541.0 | ||
007 | cr nn 008mamaa | ||
008 | 140929s2015 gw | s |||| 0|eng d | ||
020 |
_a9783319100524 _9978-3-319-10052-4 |
||
024 | 7 |
_a10.1007/978-3-319-10052-4 _2doi |
|
050 | 4 | _aTK7888.4 | |
072 | 7 |
_aTJFC _2bicssc |
|
072 | 7 |
_aTEC008010 _2bisacsh |
|
082 | 0 | 4 |
_a621.3815 _223 |
100 | 1 |
_aPour Aryan, Naser. _eauthor. |
|
245 | 1 | 0 |
_aStimulation and Recording Electrodes for Neural Prostheses _h[electronic resource] / _cby Naser Pour Aryan, Hans Kaim, Albrecht Rothermel. |
264 | 1 |
_aCham : _bSpringer International Publishing : _bImprint: Springer, _c2015. |
|
300 |
_aXII, 81 p. 58 illus., 36 illus. in color. _bonline resource. |
||
336 |
_atext _btxt _2rdacontent |
||
337 |
_acomputer _bc _2rdamedia |
||
338 |
_aonline resource _bcr _2rdacarrier |
||
347 |
_atext file _bPDF _2rda |
||
490 | 1 |
_aSpringerBriefs in Electrical and Computer Engineering, _x2191-8112 ; _v78 |
|
505 | 0 | _aStimulation and recording electrodes: General concepts -- Irreversible and reversible redox reactions: Water window -- Charge balance and safe operation conditions -- Primary current distribution and electrode geometry -- Experiments hardware and methods -- Electrode materials: State-of-the-art and experiments -- The effect of the counter electrode on stimulation electrode lifetime -- Electrode modeling for titanium nitride, iridium and iridium oxide microelectrodes -- Summary. | |
520 | _aThis book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter. | ||
650 | 0 | _aEngineering. | |
650 | 0 | _aElectronic circuits. | |
650 | 0 | _aBiomedical engineering. | |
650 | 1 | 4 | _aEngineering. |
650 | 2 | 4 | _aCircuits and Systems. |
650 | 2 | 4 | _aBiomedical Engineering. |
700 | 1 |
_aKaim, Hans. _eauthor. |
|
700 | 1 |
_aRothermel, Albrecht. _eauthor. |
|
710 | 2 | _aSpringerLink (Online service) | |
773 | 0 | _tSpringer eBooks | |
776 | 0 | 8 |
_iPrinted edition: _z9783319100517 |
830 | 0 |
_aSpringerBriefs in Electrical and Computer Engineering, _x2191-8112 ; _v78 |
|
856 | 4 | 0 | _uhttp://dx.doi.org/10.1007/978-3-319-10052-4 |
912 | _aZDB-2-ENG | ||
942 | _cEBK | ||
999 |
_c58298 _d58298 |