000 03237nam a22005535i 4500
001 978-1-4939-6556-4
003 DE-He213
005 20200421112544.0
007 cr nn 008mamaa
008 160806s2016 xxu| s |||| 0|eng d
020 _a9781493965564
_9978-1-4939-6556-4
024 7 _a10.1007/978-1-4939-6556-4
_2doi
050 4 _aTH1-9745
072 7 _aKJMV4
_2bicssc
072 7 _aBUS093000
_2bisacsh
082 0 4 _a658.2
_223
100 1 _aBlum, Andrew F.
_eauthor.
245 1 0 _aFire Hazard Assessment of Lithium Ion Battery Energy Storage Systems
_h[electronic resource] /
_cby Andrew F. Blum, R. Thomas Long Jr.
264 1 _aNew York, NY :
_bSpringer New York :
_bImprint: Springer,
_c2016.
300 _aXXI, 90 p. 55 illus.
_bonline resource.
336 _atext
_btxt
_2rdacontent
337 _acomputer
_bc
_2rdamedia
338 _aonline resource
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
490 1 _aSpringerBriefs in Fire,
_x2193-6595
505 0 _aBackground -- Literature Review and Gap Analysis -- Testing Program Summary -- ESS Description -- Testing Setup -- Test Results -- Key Findings -- Recommendations and Future Work -- Acknowledgements.
520 _aProviding a concise overview of lithium-ion (Li-ion) battery energy storage systems (ESSs), this book also presents the full-scale fire testing of 100 kilowatt hour (kWh) Li-ion battery ESSs. It details a full-scale fire testing plan to perform an assessment of Li-ion battery ESS fire hazards, developed after a thorough technical study. It documents the results of the testing plan including external and internal ignition testing, ESS positioning, temperature and heat flux measurements, pressure measurement, weather meters, and data acquisition systems. A comprehensive literature review and gap analysis reveal the current state of research into this vital aspect of energy storage. The authors cover the characteristics and hazards of Li-ion batteries, their anatomy and design, commercial and residential ESSs, historical fire incidents, and ESS codes and regulations. Researchers and professionals working in fire protection engineering, battery systems engineering, or energy storage will find this book a useful example of a fire testing plan. The results of the hazard assessment offer insights for those involved in electrical, fire, and building codes, as well as practitioners in design standards and fire testing.
650 0 _aEngineering.
650 0 _aEnergy storage.
650 0 _aElectric power production.
650 0 _aQuality control.
650 0 _aReliability.
650 0 _aIndustrial safety.
650 0 _aFacility management.
650 1 4 _aEngineering.
650 2 4 _aFacility Management.
650 2 4 _aEnergy Storage.
650 2 4 _aQuality Control, Reliability, Safety and Risk.
650 2 4 _aEnergy Technology.
700 1 _aLong Jr., R. Thomas.
_eauthor.
710 2 _aSpringerLink (Online service)
773 0 _tSpringer eBooks
776 0 8 _iPrinted edition:
_z9781493965557
830 0 _aSpringerBriefs in Fire,
_x2193-6595
856 4 0 _uhttp://dx.doi.org/10.1007/978-1-4939-6556-4
912 _aZDB-2-SCS
942 _cEBK
999 _c58479
_d58479