245 | 0 | 0 |
_aEnergy-Efficient Computing and Data Centers _h[electronic resource] / _cLuigi Brochard... [et al.]. |
260 |
_aLondon : _bISTE, Ltd. ; _aHoboken : _bJohn Wiley & Sons, Incorporated, _c2019. |
||
300 | _a1 online resource (238 p.) | ||
336 |
_atext _2rdacontent |
||
337 |
_acomputer _2rdamedia |
||
338 |
_aonline resource _2rdacarrier |
||
500 | _aDescription based upon print version of record. | ||
505 | 0 | _aCover; Half-Title Page; Title Page; Copyright Page; Contents; Introduction; Acknowledgments; 1. Systems in Data Centers; 1.1. Servers; 1.2. Storage arrays; 1.3. Data center networking; 1.4. Components; 1.4.1. Central processing unit; 1.4.2. Graphics processing unit; 1.4.3. Volatile memory; 1.4.4. Non-volatile memory; 1.4.5. Non-volatile storage; 1.4.6. Spinning disks and tape storage; 1.4.7. Motherboard; 1.4.8. PCIe I/O cards; 1.4.9. Power supplies; 1.4.10. Fans; 2. Cooling Servers; 2.1. Evolution of cooling for mainframe, midrange and distributed computers from the 1960s to 1990s | |
505 | 8 | _a2.2. Emergence of cooling for scale out computers from 1990s to 2010s2.3. Chassis and rack cooling methods; 2.4. Metrics considered for cooling; 2.4.1. Efficiency; 2.4.2. Reliability cost; 2.4.3. Thermal performance; 2.5. Material used for cooling; 2.6. System layout and cooling air flow optimization; 3. Cooling the Data Center; 3.1. System cooling technologies used; 3.2. Air-cooled data center; 3.2.1. Conventional air-cooled data center; 3.3. ASHRAE data center cooling standards; 3.3.1. Operation and temperature classes; 3.3.2. Liquid cooling classes; 3.3.3. Server and rack power trend | |
505 | 8 | _a3.4. Liquid-cooled racks3.5. Liquid-cooled servers; 3.5.1. Water heat capacity; 3.5.2. Thermal conduction module; 3.5.3. Full node heat removal with cold plates; 3.5.4. Modular heat removal with cold plates; 3.5.5. Immersion cooling; 3.5.6. Recent DWC servers; 3.6. Free cooling; 3.7. Waste heat reuse; 3.7.1. Reusing heat as heat; 3.7.2. Transforming heat with adsorption chillers; 4. Power Consumption of Servers and Workloads; 4.1. Trends in power consumption for processors; 4.1.1. Moore's and Dennard's laws; 4.1.2. Floating point instructions on Xeon processors | |
505 | 8 | _a4.1.3. CPU frequency of instructions on Intel Xeon processors4.2. Trends in power consumption for GPUs; 4.2.1. Moore's and Dennard's laws; 4.3. ACPI states; 4.4. The power equation; 5. Power and Performance of Workloads; 5.1. Power and performance of workloads; 5.1.1. SKU power and performance variations; 5.1.2. System parameters; 5.1.3. Workloads used; 5.1.4. CPU-bound and memory-bound workloads; 5.1.5. DC node power versus components power; 5.2. Power, thermal and performance on air-cooled servers with Intel Xeon; 5.2.1. Frequency, power and performance of simple SIMD instructions | |
505 | 8 | _a5.2.2. Power, thermal and performance behavior of HPL5.2.3. Power, thermal and performance behavior of STREAM; 5.2.4. Power, thermal and performance behavior of real workloads; 5.2.5. Power, thermal and frequency differences between CPUs; 5.3. Power, thermal and performance on water-cooled servers with Intel Xeon; 5.3.1. Impact on CPU temperature; 5.3.2. Impact on voltage and frequency; 5.3.3. Impact on power consumption and performance; 5.4. Conclusions on the impact of cooling on power and performance; 6. Monitoring and Controlling Power and Performance of Servers and Data Centers | |
500 | _a6.1. Monitoring power and performance of servers | ||
650 | 0 |
_aData centers _xEnergy consumption. _98525 |
|
655 | 4 |
_aElectronic books. _93294 |
|
700 | 1 |
_aBrochard, Luigi. _98526 |
|
776 | 0 | 8 |
_iPrint version: _aBrochard, Luigi _tEnergy-Efficient Computing and Data Centers _dNewark : John Wiley & Sons, Incorporated,c2019 _z9781786301857 |
856 | 4 | 0 |
_uhttps://doi.org/10.1002/9781119422037 _zWiley Online Library |
942 | _cEBK | ||
994 |
_a92 _bDG1 |
||
999 |
_c69123 _d69123 |