000 03398nam a22005535i 4500
001 978-3-319-49337-4
003 DE-He213
005 20220801220832.0
007 cr nn 008mamaa
008 170102s2017 sz | s |||| 0|eng d
020 _a9783319493374
_9978-3-319-49337-4
024 7 _a10.1007/978-3-319-49337-4
_2doi
050 4 _aTK7867-7867.5
072 7 _aTJFC
_2bicssc
072 7 _aTEC008010
_2bisacsh
072 7 _aTJFC
_2thema
082 0 4 _a621.3815
_223
100 1 _aYilmaz, Gürkan.
_eauthor.
_4aut
_4http://id.loc.gov/vocabulary/relators/aut
_952635
245 1 0 _aWireless Power Transfer and Data Communication for Neural Implants
_h[electronic resource] :
_bCase Study: Epilepsy Monitoring /
_cby Gürkan Yilmaz, Catherine Dehollain.
250 _a1st ed. 2017.
264 1 _aCham :
_bSpringer International Publishing :
_bImprint: Springer,
_c2017.
300 _aXII, 110 p. 65 illus., 60 illus. in color.
_bonline resource.
336 _atext
_btxt
_2rdacontent
337 _acomputer
_bc
_2rdamedia
338 _aonline resource
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
490 1 _aAnalog Circuits and Signal Processing,
_x2197-1854
505 0 _aIntroduction -- System Overview -- Wireless Power Transfer -- Wireless Data Communication -- Packaging of the Implant -- System Level Experiments and Results -- Conclusion.
520 _aThis book presents new circuits and systems for implantable biomedical applications targeting neural recording. The authors describe a system design adapted to conform to the requirements of an epilepsy monitoring system. Throughout the book, these requirements are reflected in terms of implant size, power consumption, and data rate. In addition to theoretical background which explains the relevant technical challenges, the authors provide practical, step-by-step solutions to these problems. Readers will gain understanding of the numerical values in such a system, enabling projections for feasibility of new projects. Provides complete, system-level perspective for implantable batteryless biomedical system; Extends design example to implementation and long term in-vitro validation; Discusses system design concerns regarding wireless power transmission and wireless data communication, particularly for systems in which both are performed on the same channel/frequency; Presents fully-integrated, implantable system and hermetically sealed packaging.
650 0 _aElectronic circuits.
_919581
650 0 _aBiomedical engineering.
_93292
650 0 _aElectronics.
_93425
650 1 4 _aElectronic Circuits and Systems.
_952636
650 2 4 _aBiomedical Engineering and Bioengineering.
_931842
650 2 4 _aElectronics and Microelectronics, Instrumentation.
_932249
700 1 _aDehollain, Catherine.
_eauthor.
_4aut
_4http://id.loc.gov/vocabulary/relators/aut
_952637
710 2 _aSpringerLink (Online service)
_952638
773 0 _tSpringer Nature eBook
776 0 8 _iPrinted edition:
_z9783319493367
776 0 8 _iPrinted edition:
_z9783319493381
776 0 8 _iPrinted edition:
_z9783319841373
830 0 _aAnalog Circuits and Signal Processing,
_x2197-1854
_952639
856 4 0 _uhttps://doi.org/10.1007/978-3-319-49337-4
912 _aZDB-2-ENG
912 _aZDB-2-SXE
942 _cEBK
999 _c78992
_d78992