000 | 03294nam a22005535i 4500 | ||
---|---|---|---|
001 | 978-3-031-79360-8 | ||
003 | DE-He213 | ||
005 | 20240730163502.0 | ||
007 | cr nn 008mamaa | ||
008 | 220601s2013 sz | s |||| 0|eng d | ||
020 |
_a9783031793608 _9978-3-031-79360-8 |
||
024 | 7 |
_a10.1007/978-3-031-79360-8 _2doi |
|
050 | 4 | _aTA174 | |
072 | 7 |
_aTBD _2bicssc |
|
072 | 7 |
_aTEC016000 _2bisacsh |
|
072 | 7 |
_aTBD _2thema |
|
082 | 0 | 4 |
_a620.0042 _223 |
100 | 1 |
_aLorenzini, Giulio. _eauthor. _4aut _4http://id.loc.gov/vocabulary/relators/aut _978829 |
|
245 | 1 | 0 |
_aSimplified Models for Assessing Heat and Mass Transfer _h[electronic resource] / _cby Giulio Lorenzini, Alessandra De Angelis, Onorio Saro, Stefano D'Elia. |
250 | _a1st ed. 2013. | ||
264 | 1 |
_aCham : _bSpringer International Publishing : _bImprint: Springer, _c2013. |
|
300 |
_aXVIII, 106 p. _bonline resource. |
||
336 |
_atext _btxt _2rdacontent |
||
337 |
_acomputer _bc _2rdamedia |
||
338 |
_aonline resource _bcr _2rdacarrier |
||
347 |
_atext file _bPDF _2rda |
||
490 | 1 |
_aSynthesis Lectures on Engineering, _x1939-523X |
|
505 | 0 | _aList of Figures -- List of Tables -- Evaporative Cooling -- Evaporative Towers Applications -- Evaporative Towers Installation -- Evaporative Towers Building Criteria -- Operating Principle -- Water Behavior and Treatment in Evaporative Towers -- Zero-Dimensional Model -- Zero-Dimensional Model Application -- Numerical Analysis -- Numerical Solution Methods -- One-Dimensional Model Application -- Conclusions. | |
520 | _aThe aim of this book is to supply valid and reasonable parameters in order to guide the choice of the right model of industrial evaporative tower according to operating conditions which vary depending on the particular industrial context: power plants, chemical plants, food processing plants and other industrial facilities are characterized by specific assets and requirements that have to be satisfied. Evaporative cooling is increasingly employed each time a significant water flow at a temperature which does not greatly differ from ambient temperature is needed for removing a remarkable heat load; its aim is to refrigerate a water flow through the partial evaporation of the same. | ||
650 | 0 |
_aEngineering design. _93802 |
|
650 | 0 |
_aMaterials. _97549 |
|
650 | 0 |
_aProfessional education. _941513 |
|
650 | 0 |
_aVocational education. _941514 |
|
650 | 1 | 4 |
_aEngineering Design. _93802 |
650 | 2 | 4 |
_aMaterials Engineering. _932311 |
650 | 2 | 4 |
_aProfessional and Vocational Education. _941516 |
700 | 1 |
_aDe Angelis, Alessandra. _eauthor. _4aut _4http://id.loc.gov/vocabulary/relators/aut _978830 |
|
700 | 1 |
_aSaro, Onorio. _eauthor. _4aut _4http://id.loc.gov/vocabulary/relators/aut _978831 |
|
700 | 1 |
_aD'Elia, Stefano. _eauthor. _4aut _4http://id.loc.gov/vocabulary/relators/aut _978832 |
|
710 | 2 |
_aSpringerLink (Online service) _978833 |
|
773 | 0 | _tSpringer Nature eBook | |
776 | 0 | 8 |
_iPrinted edition: _z9783031793592 |
776 | 0 | 8 |
_iPrinted edition: _z9783031793615 |
830 | 0 |
_aSynthesis Lectures on Engineering, _x1939-523X _978834 |
|
856 | 4 | 0 | _uhttps://doi.org/10.1007/978-3-031-79360-8 |
912 | _aZDB-2-SXSC | ||
942 | _cEBK | ||
999 |
_c84665 _d84665 |