000 08753nam a22006615i 4500
001 978-3-540-37221-9
003 DE-He213
005 20240730202617.0
007 cr nn 008mamaa
008 100301s2006 gw | s |||| 0|eng d
020 _a9783540372219
_9978-3-540-37221-9
024 7 _a10.1007/11812715
_2doi
050 4 _aTA1634
072 7 _aUYQV
_2bicssc
072 7 _aCOM016000
_2bisacsh
072 7 _aUYQV
_2thema
082 0 4 _a006.37
_223
245 1 0 _aMedical Imaging and Augmented Reality
_h[electronic resource] :
_bThird International Workshop, Shanghai, China, August 17-18, 2006, Proceedings /
_cedited by Guang-Zhong Yang, Tianzi Jiang, Dinggang Shen, Lixu Gu, Jie Yang.
250 _a1st ed. 2006.
264 1 _aBerlin, Heidelberg :
_bSpringer Berlin Heidelberg :
_bImprint: Springer,
_c2006.
300 _aXIII, 399 p.
_bonline resource.
336 _atext
_btxt
_2rdacontent
337 _acomputer
_bc
_2rdamedia
338 _aonline resource
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
490 1 _aImage Processing, Computer Vision, Pattern Recognition, and Graphics,
_x3004-9954 ;
_v4091
505 0 _aInvited Contributions -- Statistics of Pose and Shape in Multi-object Complexes Using Principal Geodesic Analysis -- Geodesic Image Normalization and Temporal Parameterization in the Space of Diffeomorphisms -- Connectivity Analysis of Human Functional MRI Data: From Linear to Nonlinear and Static to Dynamic -- Lessons from Brain Mapping in Surgery for Low-Grade Gliomas: Study of Cerebral Connectivity and Plasticity -- Shape Modeling and Morphometry -- Multi-scale Voxel-Based Morphometry Via Weighted Spherical Harmonic Representation -- An Embedding Framework for Myocardial Velocity Processing with MRI -- A Multiscale Morphological Approach to Topology Correction of Cortical Surfaces -- Finding Deformable Shapes by Point Set Matching Through Nonparametric Belief Propagation -- Robust and Accurate Reconstruction of Patient-Specific 3D Surface Models from Sparse Point Sets: A Sequential Three-Stage Trimmed Optimization Approach -- Generalized n-D C k B-Spline Scattered Data Approximation with Confidence Values -- Improved Shape Modeling of Tubular Objects Using Cylindrical Parameterization -- Patient Specific Modeling and Qualification -- Role of 3T High Field BOLD fMRI in Brain Cortical Mapping for Glioma Involving Eloquent Areas -- Noninvasive Temperature Monitoring in a Wide Range Based on Textures of Ultrasound Images -- A Novel Liver Perfusion Analysis Based on Active Contours and Chamfer Matching -- Cerebral Vascular Tree Matching of 3D-RA Data Based on Tree Edit Distance -- Application of SVD-Based Metabolite Quantification Methods in Magnetic Resonance Spectroscopic Imaging -- An Inverse Recovery of Cardiac Electrical Propagation from Image Sequences -- Surgical Simulation and Skills Assessment -- Optical Mapping of the Frontal Cortex During a Surgical Knot-Tying Task, a FeasibilityStudy -- Tracking of Instruments in Minimally Invasive Surgery for Surgical Skill Analysis -- The Effect of Depth Perception on Visual-Motor Compensation in Minimal Invasive Surgery -- Efficient and Accurate Collision Detection Based on Surgery Simulation -- Medical Simulation with Haptic and Graphic Feedback -- Surgical Guidance and Navigation -- Towards a Hybrid Navigation Interface: Comparison of a Slice Based Navigation System with In-Situ Visualization -- Surgical Navigation of Integral Videography Image Overlay for Open MRI-Guided Glioma Surgery -- Automatic Pose Recovery of the Distal Locking Holes from Single Calibrated Fluoroscopic Image for Computer-Assisted Intramedullary Nailing of Femoral Shaft Fractures -- A Framework for Image-Guided Breast Surgery -- 3D US Imaging System for the Guidance of Uterine Adenoma and Uterine Bleeding RF Ablation -- Image Registration -- A General Learning Framework for Non-rigid Image Registration -- Learning-Based 2D/3D Rigid Registration Using Jensen-Shannon Divergence for Image-Guided Surgery -- Sparse Appearance Model Based Registration of 3D Ultrasound Images -- A Neighborhood Incorporated Method in Image Registration -- Robust Click-Point Linking for Longitudinal Follow-Up Studies -- 3D Gabor Wavelets for Evaluating Medical Image Registration Algorithms -- A Novel 3D Correspondence-Less Method for MRI and Paxinos-Watson Atlas of Rat Brain Registration -- Multi-modality Image Registration Using Gradient Vector Flow Intensity -- Multi-stage Registration for Quantification of Lung Perfusion in Chest CT Images -- PET Image Reconstruction -- List-Mode Affine Rebinning for Respiratory Motion Correction in PET Cardiac Imaging -- Simultaneous Estimation of PET Attenuation and Activity Images with Divided Difference Filters -- Convergent Bayesian Reconstruction for PET Using New MRF Quadratic Membrane-Plate Hybrid Multi-order Prior -- Image Segmentation -- Automatic Segmentation of the Aortic Dissection Membrane from 3D CTA Images -- Inferring Vascular Structures in Coronary Artery X-Ray Angiograms Based on Multi-Feature Fuzzy Recognition Algorithm -- Hierarchical 3D Shape Model for Segmentation of 4D MR Cardiac Images -- An Improved Statistical Approach for Cerebrovascular Tree Extraction -- Segmentation of 3-D MRI Brain Images Using Information Propagation -- Pulsative Flow Segmentation in MRA Image Series by AR Modeling and EM Algorithm -- Abdominal Organ Identification Based on Atlas Registration and Its Application in Fuzzy Connectedness Segmentation -- An Improved 2D Colonic Polyp Segmentation Framework Based on Gradient Vector Flow Deformable Model -- Segmentation for Medical Image Using a Statistical Initial Process and a Level Set Method -- Leukocyte Detection Using Nucleus Contour Propagation.
520 _aThe Third International Workshop on Medical Imaging and Augmented Reality, MIAR 2006, was held in Shanghai, China at the Regal International East Asia Hotel during August 17-18, 2006. The goal of MIAR 2006 was to bring together researchers in medical image computing and intervention to present the state-of-the-art devel- ments in this ever-growing research area. The meeting consisted of a single track of oral/poster presentations, with each session led by an invited lecture from our dist- guished international faculty members. For MIAR 2006, we received 87 full subm- sions, which were subsequently reviewed by up to 5 reviewers, resulting in the acc- tance of 45 full papers included in this volume. For this workshop, we also included four papers from the invited speakers covering shape modeling, fMRI analysis, and study of cerebral connectivity and plasticity. Running such a workshop requires dedication, and we appreciate the commitment of the MIAR 2006 Programme Committee and reviewers who worked to a tight de- line in putting together this workshop. We would also like to thank members of the local Organizing Committee, who have been working so hard behind the scenes to make MIAR 2006 a great success. It was our great pleasure to welcome this year's MIAR attendees to Shanghai, which is the largest base of Chinese industrial technology, an important seaport and China's largest commercial and financial center.
650 0 _aComputer vision.
_9172298
650 0 _aMedical informatics.
_94729
650 0 _aRadiology.
_932514
650 0 _aArtificial intelligence.
_93407
650 0 _aComputer graphics.
_94088
650 0 _aPattern recognition systems.
_93953
650 1 4 _aComputer Vision.
_9172299
650 2 4 _aHealth Informatics.
_931799
650 2 4 _aRadiology.
_932514
650 2 4 _aArtificial Intelligence.
_93407
650 2 4 _aComputer Graphics.
_94088
650 2 4 _aAutomated Pattern Recognition.
_931568
700 1 _aYang, Guang-Zhong.
_eeditor.
_4edt
_4http://id.loc.gov/vocabulary/relators/edt
_9172300
700 1 _aJiang, Tianzi.
_eeditor.
_4edt
_4http://id.loc.gov/vocabulary/relators/edt
_9172301
700 1 _aShen, Dinggang.
_eeditor.
_4edt
_4http://id.loc.gov/vocabulary/relators/edt
_9172302
700 1 _aGu, Lixu.
_eeditor.
_4edt
_4http://id.loc.gov/vocabulary/relators/edt
_9172303
700 1 _aYang, Jie.
_eeditor.
_4edt
_4http://id.loc.gov/vocabulary/relators/edt
_9172304
710 2 _aSpringerLink (Online service)
_9172305
773 0 _tSpringer Nature eBook
776 0 8 _iPrinted edition:
_z9783540372202
776 0 8 _iPrinted edition:
_z9783540827573
830 0 _aImage Processing, Computer Vision, Pattern Recognition, and Graphics,
_x3004-9954 ;
_v4091
_9172306
856 4 0 _uhttps://doi.org/10.1007/11812715
912 _aZDB-2-SCS
912 _aZDB-2-SXCS
912 _aZDB-2-LNC
942 _cELN
999 _c97101
_d97101